Labgruppen 12K44

Labgruppen 12K44

  • Processing / Network: Lake / Dante
  • Number of amplifier channels: 4
  • Total burst power all channels (share among channels with RPM): 12000 W

 75,00

Huurperiode

Omschrijving

GeneralProcessing / Network: Lake / Dante
Number of amplifier channels: 4
Total burst power all channels (share among channels with RPM): 12000 W

Max output power (all channels driven)2 ohms: 3000W
2.67 ohms: 3000W
4 ohms: 3000W
8 ohms: 1900W
16 ohms: 950W
Hi-Z 70 V: 3000W
Hi-Z 100 V: 3000W

Max output power single channel2 ohms: 4400W
2.67 ohms: 5900W
4 ohms: 4600W
8 ohms: 2300W
16 ohms: 1150W
Hi-Z 70V: 3300W
Hi-Z 100V: 4700W

Amplifier output modules (all models, all channels)Peak output voltage: 194V
Max. output current: 67A
Rational Power Management (RPM): Regardless of model, any channel has potential to deliver the max single channel output power
Default voltage limitation (can be lifted with RPM configuration): 175 V
Protection features: Current Average Limiter (CAL), Very High Frequency Protection (VHF), Direct Current Protection (DC), Short Circuit Protection, Current-Clip Limiter, Voltage Clip Limiter, Temperature protection

Audio Performance (Amplifier platform with digital input)THD + N 20 Hz – 20 kHz for 1 W: < 0.05 %
THD + N at 1 kHz and 1 dB below clipping: < 0.04 %
Dynamic range: > 114 dB
Channel separation (Crosstalk) at 1 kHz: > 70 dB
Frequency response (1 W into 8 Ohm, 20 Hz – 20 kHz): +/- 0.05 dB
Internal Sample Rate / Data path: 48 / 96 kHz / 32 bit floating point
Product propagation delay AES 96 kHz / analog input: 1.61 / 1.68 ms

Lake processingLoudspeaker processing: Up to 4 modules of Classic/linear-phase/FIR crossover, EQ, delay, LimiterMax™ – peak and RMS limiters
System tuning: Group control with Raised Cosine™ MESA EG™ asymmetric filters
Input redundancy / Matrix: Automatic 4 level input redundancy / 4 input mixers
System integration: Comprehensive 3rd party protocol over UDP Ethernet

Measurement & AnalysisPilot tone generation and analysis: Yes
Load impedance analysis: Yes
Real Time Analyzer (RTA), 3rd party integration: Yes

Dante Audio NetworkDante I/O: 8 x 8
Network topology / redundancy: Flexible topology / Supports daisy-chained and Dual redundant networks
Sample Rates / Transport: 48, 96 kHz / Uni + Multicast
Network latency: 0.25, 0.5, 1.0, 2.0, 5.0 ms

Device presets
Local memory locations for the settings of the product: 100

AES InputsInputs: 4 AES inputs
Supported sample rates / resolution: 44.1, 48, 88.2, 96, 176.4, 192 kHz / up to 24 bits
Sample rate conversion THD+N 20 Hz – 20 kHz unweighted: 0.00003 %

Analog InputsInputs: 4 high quality inputs with Iso-Float ground isolation
Maximum input / digital reference: +26 dBu / +21 dBu
Sampling rate / Resolution: 96 kHz / 24 bit
Input impedance balanced / unbalanced: 20 / 10 kOhm
THD+N (typical at 1 kHz unweighted): 0.00022 %
THD+N (typical at 20 Hz and 20 kHz unweighted): 0.00033 %

LimitersAdjustable Inter-Sample Voltage Peak Limiter (ISVPL): 17.8 – 194 V, step size 0.1 V
Current Peak Limiter < 300 ms: 67 A peak
Current Average Limiter (CAL) > 300 ms: 33 Arms
MaxRMS (rms voltage limiter): Yes
MaxPeak (peak voltage limiter): Yes

GainAmplifier gain: 22 – 44 dB, step size 0.1 dB
Output attenuator: -Inf to 0 dB, step size 0.25 dB

Back panel InterfaceAnalog, 2-channel I/O (input + link): 4 x 3-pin XLR, electronically balanced
AES / EBU / I/O (input + link): 2 x 3-pin XLR
Output connectors: Neutrik speakON (1 x NLT8, 2 x NLT4) or 4 Binding Posts (pairs)
Auto 10/100, Auto Uplink: 2 x RJ45 etherCON
Control and monitoring interface: Via Ethernet for Lake Controller software, or DLM (the 3rd party protocol)
Detachable mains cord: Neutrik PowerCon rated at 250V/32A
Cooling: Three fans, front-rear airflow, temperature controlled speed

Front-panel user interfaceDisplay: 2.5 inch, black / white, daylight readable LCD
Fault/Warning/Limit/Clip indicators: RGB LEDs and detailed fault description on display
Mute and soft function: buttons 8 provided
Standby Power button: On/Standby
Mute Enable button: Enables muting of outputs and inputs via soft-button keypad
Meter button: Toggles through meter views
Menu button: Provides a menu driven interface for full function front panel control
Rotary Encoder: Yes
Exit Button: Provides a “back” function

Mains PowerNominal voltage: 100 – 240 Volt AC 45 – 66 Hz
Operating voltage: 70-265 V AC
Mains wall plug: NEMA L5-30 “Twist lock” 125 V / 30 A, and CEE 7/7 “Schuko” 230 V / 16 A

Power supply featuresSoft start / Inrush power: Yes/ Max 8 Ampere
Power Factor Correction (PFC): 0.98
Regulated switch mode power supply (R.SMPS): Yes
Breaker Emulation Limiter (BEL): Configurable current threshold and breaker profile
BEL max current threshold: 25 A
Power Average Limiter (PAL): Yes
Under Voltage Limiter (UVL): Yes
Mains undervoltage and overvoltage protection and mains glitch tolerance: Yes

DimensionsRack rail to rear panel: W: 483 mm (19″), H: 88 mm (2 U), D: 424 mm (16″)
Overall depth front-rear support: D: 498 mm (19.6″)

Weight: 16.5 kg

Telefoon:

0418-843638

 

Adres:

Weteringshoek 30
5328 BN Rossum

© VDL-Sound | All Rights Reserved.

Neem contact met ons op

Heb je een vraag, wil je meer informatie over onze diensten of ben je benieuwd naar wat we voor jouw evenement kunnen betekenen? Vul het onderstaande contactformulier in en we nemen zo snel mogelijk contact met je op. Bij VDL Sound denken we graag met je mee om jouw geluidservaring naar een hoger niveau te tillen. Of het nu gaat om geluidsverhuur, techniek, of complete evenementondersteuning, wij staan klaar om je te helpen.